29 research outputs found

    Zero overshoot and fast transient response using a fuzzy logic controller

    Get PDF
    In some industrial process control systems it is desirable not to allow an overshoot beyond the setpoint or a threshold, this could be a safety constraint or the requirement of the system. This paper outlines our work in designing a fuzzy PID controller to achieve a step-response with zero overshoot while improving the output transient response. Our designed fuzzy PID controller is applied to stable, marginally stable and unstable systems and their step responses are compared with a tuned conventional PID controller. A comparative case study shows that the proposed fuzzy controller is highly effective and outperforms the PID controller in achieving a zero overshoot response and enhancing the output transient response

    Design of a wireless intelligent fuzzy controller network

    Get PDF
    Since the first application of fuzzy logic in the field of control engineering, fuzzy logic control has been successfully employed in controlling a wide variety of applications, such as commercial appliances, industrial automation, robots, traffic control, cement kilns and automotive engineering. The human knowledge on controlling complex and non-linear processes can be incorporated into a controller in the form of linguistic expressions. Despite these achievements, however, there is still a lack of an empirical or analytical design study which adequately addresses a systematic auto-tuning method. Indeed, tuning is one of the most crucial parts in the overall design of fuzzy logic controllers and it has become an active research field. Various techniques have been utilised to develop algorithms to fine-tune the controller parameters from a trial and error method to very advanced optimisation techniques. The structure of fuzzy logic controllers is not straightforward as is the case in PID controllers. In addition, there is also a set of parameters that can be adjusted, and it is not always easy to find the relationship between the parameters and the controller performance measures. Moreover, in general, controllers have a wide range of setpoints; changing from one value to another requiring the controller parameters to be re-tuned in order to maintain a satisfactory performance over the entire range of setpoints. This thesis deals with the design and implementation of a new intelligent algorithm for fuzzy logic controllers in a wireless network structure. The algorithm enables the controllers to learn about their plants and systematically tune their gains. The algorithm also provides the capability of retaining the knowledge acquired during the tuning process. Furthermore, this knowledge is shared on the network through a wireless communication link with other controllers. Based on the relationships between controller gains and the closed-loop characteristics, an auto-tuning algorithm is developed. Simulation experiments using standard second order systems demonstrate the effectiveness of the algorithm with respect to auto-tuning, tracking setpoints and rejecting external disturbances. Furthermore, a zero overshoot response is produced with improvements in the transient and the steady state responses. The wireless network structure is implemented using LabVIEW by composing a network of several fuzzy controllers. The results demonstrate that the controllers are able to retain and share the knowledge

    Radiometric Wireless Sensor Network Monitoring of Partial Discharge Sources in Electrical Substations

    Get PDF
    A wireless sensor network (WSN) with the potential to monitor and locate partial discharge (PD) in high-voltage electricity substations using only received signal strength (RSS) is proposed. The advantages of an RSS-based operating principle over more traditional methods (e.g., time-of-arrival and time-difference-of-arrival) are described. Laboratory measurements of PD that emulate the operation of a PD WSN are presented. The hardware architecture of a prototype PD WSN is described and the particular challenges of an RSS-based location approach in an environment with an unknown, and spatially varying, path-loss index are discussed. It is concluded that an RSS-based PD WSN is a plausible solution for the monitoring of insulation integrity in electricity substations

    Diagnostic Potential of Free-Space Radiometric Partial Discharge Measurements

    Get PDF
    The work reported in this paper addresses the calibration of four types of partial discharge (PD) emulator required for the development of a PD Wireless Sensor Network (WSN). Three partial discharge (PD) emulators have been constructed: a floating-electrode emulator, and two internal PD emulators. Both DC and AC HV power supplies are used to initiate PD which is measured using concurrent free-space radiometry (FSR) and a galvanic contact method based on the IEC 60270 standard. A new method of estimating absolute PD activity level from a radiometric measurement is proposed

    Partial Discharge Localization Based on Received Signal Strength

    Get PDF
    Partial Discharge (PD) occurs when insulation containing defects or voids is subject to high voltages. If left untreated PD can degrade insulation until, eventually, catastrophic insulation failure occurs. The detection of PD current pulses, however, can allow incipient insulation faults to be identified, located and repaired prior to plant failure. Wireless technology has paved the path for PD detection and monitoring. Software Defined Radio (SDR) is a promising technology. Signals from two PD sources are received at six outdoors locations using an SDR USRP N200 which is connected to a laptop. PD sources, thereafter, are localized based on received signal strengths

    Low power radiometric partial discharge sensor using composite transistor-reset integrator

    Get PDF
    The measurement of partial discharge provides a means of monitoring insulation health in high-voltage equipment. Traditional partial discharge measurements require separate installation for each item of plant to physically connect sensors with specific items. Wireless measurement methods provide an attractive and scalable alternative. Existing wireless monitoring technologies which use time-difference-of-arrival of a partial discharge signal at multiple, spatially separated, sensors place high demands on power consumption and cost due to a requirement for rapid sampling. A recently proposed partial discharge monitoring system using a wireless sensor network and measuring received signal strength only, has potential cost and scalability advantages. An incoherent wireless sensor incorporating a transistor-reset integrator has been developed that reduces the measurement bandwidth of the PD events and alleviates the need for high-speed sampling. It is based on composite amplifier techniques to reduce the power requirements by a factor of approximately four without compromising precision. The accuracy of the proposed sensor is compared to that obtained using a high-speed digital sampling oscilloscope. Received energies were measured over a 10 m distance in 1 m increments and produced an error within 1 dB beyond 4 m and 3.2 dB at shorter distances, resulting in a measurement accuracy within 1 m

    Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in HV Equipment

    Get PDF
    Monitoring of partial discharge (PD) activity within high voltage electrical environments is frequently used for the assessment of insulation condition. Traditional measurement techniques employ technologies that require either offline installation or high power consumption and cost. A wireless sensor network is proposed that utilizes only received signal strength to locate partial discharge within a high-voltage electricity Substation. The network comprises low-power and lowcost radiometric sensor nodes which receive the radiation propagated from a source of partial discharge. Results are reported from a test performed within a large indoor environment with a network of nine sensor nodes. An emulated PD source was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location

    Partial discharge detection using low cost RTL-SDR model for wideband spectrum sensing

    Get PDF
    Partial discharge (PD) is one of the predominant factors to be controlled to ensure reliability and undisrupted functions of power generators, motors, Gas Insulated Switchgear (GIS) and grid connected power distribution equipment, especially in the future smart grid. The emergence of wireless technology has provided numerous opportunities to optimise remote monitoring and control facilities that can play a significant role in ensuring swift control and restoration of HV plant equipment. In order to monitor PD, several approaches have been employed, however, the existing schemes do not provide an optimal approach for PD signal analysis, and are very costly. In this paper an RTL-SDR (Software Defined Radio) based spectrum analyser has been proposed in order to provide a potentially low cost solution for PD detection and monitoring. Initially, a portable spectrum analyser has been used for PD detection that was later replaced by an RTL-SDR device. The proposed schemes exhibit promising results for spectral detection within the VHF and UHF band

    Mapping 123 million neonatal, infant and child deaths between 2000 and 2017

    Get PDF
    Since 2000, many countries have achieved considerable success in improving child survival, but localized progress remains unclear. To inform efforts towards United Nations Sustainable Development Goal 3.2—to end preventable child deaths by 2030—we need consistently estimated data at the subnational level regarding child mortality rates and trends. Here we quantified, for the period 2000–2017, the subnational variation in mortality rates and number of deaths of neonates, infants and children under 5 years of age within 99 low- and middle-income countries using a geostatistical survival model. We estimated that 32% of children under 5 in these countries lived in districts that had attained rates of 25 or fewer child deaths per 1,000 live births by 2017, and that 58% of child deaths between 2000 and 2017 in these countries could have been averted in the absence of geographical inequality. This study enables the identification of high-mortality clusters, patterns of progress and geographical inequalities to inform appropriate investments and implementations that will help to improve the health of all populations

    Mapping local patterns of childhood overweight and wasting in low- and middle-income countries between 2000 and 2017

    Get PDF
    A double burden of malnutrition occurs when individuals, household members or communities experience both undernutrition and overweight. Here, we show geospatial estimates of overweight and wasting prevalence among children under 5 years of age in 105 low- and middle-income countries (LMICs) from 2000 to 2017 and aggregate these to policy-relevant administrative units. Wasting decreased overall across LMICs between 2000 and 2017, from 8.4% (62.3 (55.1–70.8) million) to 6.4% (58.3 (47.6–70.7) million), but is predicted to remain above the World Health Organization’s Global Nutrition Target of <5% in over half of LMICs by 2025. Prevalence of overweight increased from 5.2% (30 (22.8–38.5) million) in 2000 to 6.0% (55.5 (44.8–67.9) million) children aged under 5 years in 2017. Areas most affected by double burden of malnutrition were located in Indonesia, Thailand, southeastern China, Botswana, Cameroon and central Nigeria. Our estimates provide a new perspective to researchers, policy makers and public health agencies in their efforts to address this global childhood syndemic
    corecore